  PHANTECH MEDICAL
  • Home
  • Phantoms
    • All Phantoms
    • Preclinical Nuclear Medicine Phantoms
    • Preclinical Computed Tomography Phantoms
    • Preclinical Magnetic Resonance Imaging Phantoms
    • Optical Phantoms
    • Fluorescence Microscopy Phantoms
    • Radioluminescence Phantoms
    • Magnetic Particle Imaging Phantoms
    • Custom Phantoms
  • About
  • Technology
  • Contact

Multi-isotope Phantom

Picture
Picture
Picture
Key features
• Phantech’s linear-filling technology
      -~60 second to fill
      -Luer lock fittings ensure no spilling
      -No bubbles
      -Videos provided for step-by-step guidance
• Resolution rods and image quality volume in a single connected channel
• Scan two isotopes that are separated and mixed in the same phantom, or scan three isotopes simultaneously
• Automatic segmentation and analysis with Imalytics (Gremse-IT) Preclinical Software
      -Resolution (FWHM) 
      -Spectrally unmix two radioisotopes mixed in the same solution
• Custom sizing available
• Compatible with most imaging systems and modalities, including MRI
Description & Applications
Phantech’s Multi-isotope phantoms are designed to allow scanning more than one isotope at a time. Users can fill two channels with different radioisotopes, and fill the third with a mixture of two radioisotopes. Some imaging systems have the ability to spectrally unmix the energy peaks of different radioisotopes. Alternatively, users can fill all three channels with different radioisotopes. 

Designed with one continuous channel, a larger image quality void and rods with different diameters can be all be filled quickly, easily and safely with a single syringe. Each end can then be sealed with luer lock caps to prevent leaking. 

Common applications:
  • Spectral unmixing
  • Image quality assessment
  • Resolution characterization
  • Image quality assessment
  • Reconstruction optimization
  • Multi-modality applications
  • ​Standardization
  • Training
  • Marketing​
Available s​izes
TEXT

Standard Rod sizes​

Customization
Yes, we can customize our Multi-isotope phantoms. Customization options include changing rod sizes, image quality void size, and overall phantom length and diameter. 

​Contact us at [email protected] for custom requests!
image and video gallery
Picture
Text
Picture
Text
Picture
Text
Picture
Text
SPecificiation sheet
Phantech_Multi-isotope_SpecSheet.pdf
File Size: 2123 kb
File Type: pdf
Download File

INNOVATIVE DESIGN


Text
Picture
Text
AUTOMATED ANALYSIS WITH IMALYTICS PRECLINICAL (GREMSE-IT)
Automated Analysis Workflow
1. Fill Multi-isotope phantom
2. Perform imaging scan
3. Load image file into Imalytics 
4. Select the phantom from the dropdown menu
5. Generate and save report
Picture
ORDER!
Lead time: <2 weeks.
Email [email protected] for quotes and custom requests.